Quantity
|
Total
|
||
|
|
|||
|
|
|||
The MultiPlus 48/5000/70-100 hybrid inverter is a flagship high-tech inverter-charger from Victron Energy, combining a powerful pure sine wave inverter rated at 5 kVA (4 kW), an intelligent battery charger (48 V, 70 A), and an ultra-fast automatic transfer switch (ATS) rated at 100 A in a single compact housing. This model serves as a key component for deploying advanced Energy Storage Systems (ESS).
The device is designed for integration into off-grid, backup, grid-tied, and hybrid electrical systems. Its architecture features flexible scalability: the inverters can be combined in parallel chains (up to 30 kVA in a single-phase configuration) or configured into three-phase networks with a total power capacity of up to 90 kVA.
Thanks to proprietary PowerControl and PowerAssist technologies, the MultiPlus 48/5000/70-100 represents an ideal solution for high-efficiency solar power plants, backup power for large private residences, commercial facilities, agricultural objects, and mobile transport applications.
Key Advantages of the MultiPlus Inverter
Most of the technical parameters of this model significantly surpass analogs from European competitors and leave budget Asian devices far behind.
- High power: nominal – 5000 VA (4000 W), excellent peak overload capacity – 10,000 W. The inverter flawlessly handles the high startup currents of heavy equipment, compressors, and electric motors.
- Pure sine wave 230 V – 100% guarantee of safe and correct operation for even the most sensitive electronics (gas boilers, servers, medical devices).
- Record efficiency up to 95% – energy conversion occurs with minimal losses and extremely low heat generation from the power components.
- Energy saving in sleep mode – the device consumes only up to 15 W when operating in the economical Search Mode.
- Perfect compatibility with LiFePO4 – a wide input voltage range (38–66 V) and flexible settings allow the adaptive 4-stage charge algorithm to be adjusted for any type of lithium, lead-acid (AGM/GEL), or carbon batteries.
- Extreme endurance (temperature range -40…+65°C) – the device is designed for uninterrupted operation under the harshest climatic conditions. It is excellent for outdoor installation in thermal enclosures, unheated rooms, attics, as well as in the utility cabins of special vehicles and marine vessels.
- Full compatibility with any generator types – the inverter works flawlessly in tandem with gasoline, diesel, inverter, and gas power plants. Flexible configuration allows automatic management of dry contacts (generator start/stop) based on the load level or battery state of charge (SoC).
- Wide range of control options — detailed monitoring, calibration, and software updates are available locally via PC or remotely via the Internet.
- Integration into the VRM ecosystem - a free cloud portal for complete remote control of your power system from anywhere in the world. It allows setting up PUSH notifications for any system events (grid failure, critical battery discharge, generator start) and process automation.
Technological Features
1. Two Independent AC Outputs
The first output is uninterruptible (main): it instantly takes over the power supply of critical loads during public grid failures. The second output is auxiliary: active only when external power (grid or generator) is available, protecting the battery bank from rapid discharge by non-essential consumers (boilers, irrigation systems, electric stoves).
2. PowerControl – Intelligent Protection of the External Grid Against Overload
You can set a strict current limit for a generator or a weak shore power line. The inverter will take this limitation into account and distribute energy: primarily to power the connected loads, and the remaining part to safely charge the batteries, preventing input circuit breakers from tripping.
3. PowerAssist – Power Boosting Function at Peak Loads
If the grid or generator capacity is insufficient to start heavy equipment, the MultiPlus will automatically add the missing energy from the batteries. Once the load decreases, the surplus power is again directed toward charging the batteries.
4. Full Support for Solar Generation
MultiPlus integrates perfectly into hybrid and off-grid systems with Victron solar MPPT charge controllers or third-party grid-tied PV inverters. The device operates in self-consumption, backup (UPS), and completely off-grid modes.
5. Remote Monitoring Worldwide
When connecting system controllers (Cerbo GX, Ekrano GX) or using the VE.Bus Smart Dongle via Bluetooth, you gain total control over the power station directly from your smartphone or via a web browser.
6. Remote and Local System Configuration
Using the MK3-USB interface for PC or the VRM cloud portal, engineers can remotely modify any inverter parameters: charging profiles, current limits, programmable relay logic, and protection configurations.
7. Power Supply System Scaling
Parallel and three-phase connection technology allows combining up to 6 devices in a single phase or building powerful three-phase clusters. This is the optimal choice for large private residences, production facilities, and commercial enterprises.
Fields of Application
- Autonomous and backup power supply for private houses and cottages;
- Office centers, banks, and commercial real estate for backup power and tariff optimization;
- Farms and agricultural facilities for uninterruptible power supply of powerful pump groups and chillers;
- Premium transport, yachts, caravans, and motorhomes – complete energy independence on the move;
- Production workshops and facilities – high-quality power supply for machine tools and industrial equipment;
- Hybrid Solar Power Plants (ESS) – joint operation with PV inverters and modern lithium batteries;
- Backup power for critical infrastructure (telecommunications, server nodes, IT sector, security systems).
Certified to Automotive EMC Standard ECE R10-4 (EMC)
ECE R10-4 is a strict international regulation for electromagnetic compatibility (EMC), mandatory for all electronic equipment installed in vehicles. It confirms the absence of emitted interference and the protection of the device itself against external electromagnetic fields.
What does the ECE R10-4 certificate mean for Victron Energy equipment?
Minimal level of electromagnetic footprint
– An operating inverter does not create radio-frequency interference or noise capable of disrupting the correct operation of onboard radio stations, GPS receivers, cellular communication modules, or engine electronic control units of vehicles and vessels.
High resistance to external interference
– The power part of the device operates without failure under conditions of unstable onboard voltage, impulse current surges, and strong magnetic fields (typical for trucks, buses, and special machinery).
Safe integration into vehicle electrical wiring
– Full compliance with UN ECE directives allows for the legal integration of Victron Energy devices into any transport without the risk of damaging factory electronics and standard safety systems (e.g., ABS, ESP).
Official confirmation of premium quality
– Compliance with the ECE R10-4 standard proves that Victron Energy products have passed strict laboratory tests and meet the highest global safety requirements for mobile applications.
What does this give to owners of Inverter Smart equipment?
- The possibility of legal installation of the device in vehicles without the risk of losing the factory warranty.
- Ideal neighborhood with other equipment – a complete absence of interference on the screens of echo sounders, navigation monitors, autopilots, and audio systems.
- Reliable and long-lasting operation in the harshest operating conditions – on commercial vehicles, expedition equipment, and small vessels.
- High level of hardware protection – the inverter is protected from failure during sharp drops or surges in the vehicle's power supply grid.
Communication Interfaces
-
System VE.Bus Port – the main information channel for configuration, parallel/three-phase operation, as well as data exchange with GX controllers for Internet connectivity.
-
Programmable Relay (dry contact) – a convenient tool for automating any processes (e.g., starting a generator when batteries are discharged).
- Built-in Bluetooth (optional) – utilizing the VE.Bus Smart Dongle module unlocks the ability for precise configuration and monitoring of the device from a smartphone via the VictronConnect app.
- PC Connection Interface (optional) – the Interface MK3-USB (VE.Bus to USB) cable allows connecting the inverter to a computer for deep programming.
Supports ESS (Energy Saving System)
Victron ESS is a smart energy system of the new generation, providing:
- Intelligent management of energy sources (grid/generator, battery, sun) with constant priority given to renewable energy.
- 24/7 power backup – critical loads are secured against any accidents in the public grid.
- Optimization of self-consumption – maximizing the use of solar energy directly for the facility's needs.
- Flexible adaptation to electricity tariffs – charging the battery bank at night (cheap rate), discharging during peak daytime hours, or according to any other set schedule.
- Visualization via VRM – detailed analytics, interactive graphs, event logs, and remote technical support.
The main goal of the ESS system is a significant reduction in electricity costs and comprehensive protection of consumers against regular or emergency power outages. The ESS system is customized for specific use case scenarios to achieve maximum energy independence.
LiFePO₄ Support with Data Exchange – Safety and Accuracy
MultiPlus 48/5000/70-100 is fully compatible with modern lithium batteries, including LiFePO₄ with BMS, via VE.Bus and/or VE.Can interfaces. Full data exchange allows:
- Measuring SOC (state of charge) with maximum accuracy.
- Preventing overcharging or deep discharge of cells, eliminating damage to the battery bank.
- Automatically limiting charge/discharge currents or disconnecting loads when the battery parameters go beyond critical limits.
- Synchronizing the inverter's charge profile in strict compliance with the battery manufacturer's recommendations.
- Recording all BMS warnings and critical triggers in the cloud event log.
- Preserving the official factory warranty for expensive batteries throughout their entire service life.
This is critical for ensuring fire safety, extending service life, and stable operation of batteries in modern power systems.